DreamStation BiPAP AVAPS

Noninvasive ventilator

Find similar products

Every patient suffering from chronic respiratory disease has changing therapeutic demands. With DreamStation BiPAP AVAPS noninvasive ventilation solutions, you have the power to treat them that way. Using clinically proven therapy solutions, DreamStation noninvasive ventilators adapt to these changing patient needs, helping to normalize ventilation.

Specifications

General
General
Humidification
  • Heated humidification: fixed, adaptive
Data storage capacity (minimum)
  • SD card: 6 months, On-board: 3 months
Filters
  • Reusable pollen; disposable ultra-fine
Device controls
  • LCD, control dial/push button
Warranty
  • 2 years (US)
Prescription guidelines
Prescription guidelines
Ventilation pressure
  • 4 to 30 cm H2O (increment is .5 cm H2O)
  • EPAP: 4 to 25 cm H2O (increment is .5 cm H2O)
  • CPAP max pressure is 20 cm H2O
Modes
  • CPAP, S, S/T, T, PC
Breath per minute
  • 1 to 30 (increment is 1 breath)
Digital Auto-Trak
  • No settings – fully automated triggering, cycling and leak compensation
AVAPS
  • Target volume: 200 to 1500 ml per breath (increment is 10 ml)
  • Max. IPAP: 6 cm H2O to 30 cm H2O
  • Min. IPAP: EPAP plus 2 cm H2O to 30 cm H2O (Minimum Pressure support is 2 cm H2O)
Inspiration time
  • .5 to 3.00 seconds (increment is .1 seconds)
Rise time
  • 1 to 6
Ramp time
  • 5 to 40 minutes (increment is 5 minutes)
Flex pressure relief
  • 0 to 3 (only in S-mode)
Humidification
  • Heated humidification, fixed, adaptive (standard 15mm or 15 mm heated tube)
Dimensions and weight
Dimensions and weight
Dimensions
  • 15.7 x 19.3 x 8.4 cm (w/o humidifier) ; 29.7 x 19.3 x 8.4 cm (w humidifier)
Weight
  • 1.33 kg/2.94 lbs (w/o humd); 1.98 kg/4.37 lbs (w humid); Incl power supply
Electrical - IntelliBridge EC40/80
Electrical - IntelliBridge EC40/80
Voltage
  • 100 – 240 VAC
Frequency
  • 50/60 Hz
Amperage
  • 2.0-1.0 A
General
General
Humidification
  • Heated humidification: fixed, adaptive
Data storage capacity (minimum)
  • SD card: 6 months, On-board: 3 months
Prescription guidelines
Prescription guidelines
Ventilation pressure
  • 4 to 30 cm H2O (increment is .5 cm H2O)
  • EPAP: 4 to 25 cm H2O (increment is .5 cm H2O)
  • CPAP max pressure is 20 cm H2O
Modes
  • CPAP, S, S/T, T, PC
See all specifications
General
General
Humidification
  • Heated humidification: fixed, adaptive
Data storage capacity (minimum)
  • SD card: 6 months, On-board: 3 months
Filters
  • Reusable pollen; disposable ultra-fine
Device controls
  • LCD, control dial/push button
Warranty
  • 2 years (US)
Prescription guidelines
Prescription guidelines
Ventilation pressure
  • 4 to 30 cm H2O (increment is .5 cm H2O)
  • EPAP: 4 to 25 cm H2O (increment is .5 cm H2O)
  • CPAP max pressure is 20 cm H2O
Modes
  • CPAP, S, S/T, T, PC
Breath per minute
  • 1 to 30 (increment is 1 breath)
Digital Auto-Trak
  • No settings – fully automated triggering, cycling and leak compensation
AVAPS
  • Target volume: 200 to 1500 ml per breath (increment is 10 ml)
  • Max. IPAP: 6 cm H2O to 30 cm H2O
  • Min. IPAP: EPAP plus 2 cm H2O to 30 cm H2O (Minimum Pressure support is 2 cm H2O)
Inspiration time
  • .5 to 3.00 seconds (increment is .1 seconds)
Rise time
  • 1 to 6
Ramp time
  • 5 to 40 minutes (increment is 5 minutes)
Flex pressure relief
  • 0 to 3 (only in S-mode)
Humidification
  • Heated humidification, fixed, adaptive (standard 15mm or 15 mm heated tube)
Dimensions and weight
Dimensions and weight
Dimensions
  • 15.7 x 19.3 x 8.4 cm (w/o humidifier) ; 29.7 x 19.3 x 8.4 cm (w humidifier)
Weight
  • 1.33 kg/2.94 lbs (w/o humd); 1.98 kg/4.37 lbs (w humid); Incl power supply
Electrical - IntelliBridge EC40/80
Electrical - IntelliBridge EC40/80
Voltage
  • 100 – 240 VAC
Frequency
  • 50/60 Hz
Amperage
  • 2.0-1.0 A
  • ¹Murphy, Patrick, et al. “The effect of volume targeted pressure support (PS) ventilation with autotitrating expiratory positive airways pressure (EPAP) and back up rate (BUR) on sleep quality in COPD-obstructive sleep apnoea (OSA) overlap syndrome.” European Respiratory Journal 42.Suppl 57 (2013): P2583. With respiratory insufficiency patients diagnosed with COPD.
  • ² Windisch, Wolfram. "Average Volume-Assured Pressure Support in Obesity Hypoventilation." CHEST 130 (2006): 815 With respiratory insufficiency patients diagnosed with Obesity Hypoventilation Syndrome
  • ³2016 Internal assessment of leading competitive BiPAP devices with backup breath rate comparing Resmed Lumis and AirCurve NIV product lines.
  • *With respiratory insufficiency patients diagnosed with Obesity Hypoventilation Syndrome
  • †Windisch, Wolfram. "Average Volume-Assured Pressure Support in Obesity Hypoventilation." CHEST 130 (2006): 815

You are about to visit a Philips global content page

Continue

You are about to visit a Philips global content page

Continue

Our site can best be viewed with the latest version of Microsoft Edge, Google Chrome or Firefox.